Previous page Introduction to Test Facilities Next page

Electrical constraints
lightning, EM Pulse, High Power MicroWaves

 

Several impulse generators are available at NUCLETUDES:

  • EIT 10000
  • HAEFELY generators
  • MIG generators
  • High frequency test bench for electrical components

 

EIT 10000

Amplitude : 80 kV / 20 ohms
Rise time : 18 ns (10% - 90%)
Fall time : 300 ns (mid-height)
Temporal shape : bi-exponential

 

HAEFELY generators

Type Amplitude Charge Tm Td Forme
Type 1  7 kV 5 ohms 6.4 µs 70 µs  biexp
Type 2  7 kV  5 ohms  0.5 µs  170 µs  biexp
Type 3  7 kV  5 ohms 0.1 µs   6.4 µs  biexp

 

Type Amplitude Charge Fréquences Forme
Type 4 3.2 kV 25 ohms 1 / 4.5 / 10 MHz Sinusoïde amortie
Type 5 3.2 kV 25 / 40 ohms 20 / 50 MHz Sinusoïde amortie

 

 

MIG-OS-MB generator


Single Pulse 0.1/6.4 μs
Single Pulse 1 MHz
Single Pulse 10 MHz
MIG-OS-MB Control and ranges (Multiple Stroke)
MIG-OS-MB Control and ranges (Multiple Burst)
Spikes and Burst equaly spaced

 

 

   

 

MIG-O600-SS generator

PIN injection: W4 6.4/70μs, W5A 40/120μs, W5B 50/500μs:
Cable Bundle-Single Stroke: W1 6.4/70us Cable Induction
Cable Bundle-Single Stroke: W4 6.4/70us Ground Injection
Cable Bundle-Single Stroke: W5A 40/120μs Cable Induction
Cable Bundle-Single Stroke: W5A 40/120μs Ground Injection
Cable Bundle-Single Stroke: W5B 50/500μs Cable Induction
Cable Bundle-Single Stroke: W5B 50/500μs Ground Injection