Electromagnetic Pulse strip line

 

This EMP strip line can be used in pulse or CW (Continuous Wave) modes. Its size makes it compatible with large equipment and complete electrical chains (volume : 7 m x 3 m x 1.8 m).

Pulse mode

- Rise time (10% - 90%) : 10 ns
- Pulse width at half maximum : 250 ns
- Time history : bi-exponential
- Standard electrical field : 50 kV/m
- Maximum value (@ h = 80 cm) : 100 kV/m
- Illumination volume : 1m x 1m x 0,8m

 

CW mode

- Strip line bandwidth : 500 MHz



Instrumentation

- 2 E field sensors (derivative passive sensor)
- 2 H field sensors (derivative passive sensor)
- Optical link 1 GHz (44 dB gain)